JVVMEG-HCD80-RFM is equipped with air cleaning system
of negative pressure exhaust air;It is used for radiation shielding
in the repacking process of radioactive drugs.
The heating chamber is composed of three parts. The control
area is located in the upper part, and the air cleaning unit and
high efficiency air filtration unit are installed. The control panel
is easy to use and observe by the operator. The working area is
located in the middle, and the front is installed with lead glass
Windows and two handling hand holes for entering the working
area; The auxiliary area was located in the lower part, and the
shielding well of the activity meter and ionization chamber and
the radioactive material delivery device were installed, which
fully met the use function of radioactive medicine in the process
of repacking.
cGMP biological cleanliness level working area
1) Configured with vertical laminar negative pressure ventilation system
Material as Integrated SS314 profile
2) Cleanliness: Class A grade (IS0100)
3) Air supply model:Vertical laminar flow
4) Laminar wind speed: 0.35-0.56m /s
5) Demand air volume :500 m3/h
6) Sealing way:Air inflating
7) Exhaust air filtration: fully efficient HEPA99.995% @0.5um (H14)
8) Exhaust air filtration:Radioactive gas filter adsorption
·Lead shielding conforming to ICRP radiation environmental safety standards
1) Front side:80mmPB
2) Left/right side:75mmPB
3)
·
Target line shielding:70mmPB
Ergonomically designed operation control panel
1) Control: The human-machine interaction interface controls and feeds back all information
2) Visible lead glass Windows; 320 mm(w)*220 mm(h)
3) Dose monitoring display: integrated in human-machine interaction interface
·Size
1) Internal dimensions :850 mm (w)*590 mm (d)*680 mm (h)
2) External dimensions: 1125 (w)*1078(d) *2400 (h)
3) Accessories: lamp, UV lamp, ozone sterilization device, power socket, etc